The evidence scoreboard
Is Garmin heart rate accurate?
Garmin is the most-published brand in the wearable literature and almost none of it measures the thing people ask about. Here is the whole Garmin record, including the parts that are empty.
We earn a commission when you buy through our Amazon links, at no extra cost to you. It never decides a ranking — the rubric that does is published in full, so you can check us rather than take our word for it. How this works.

Top pick
Anyone who trains by heart ratePolar H10
The device other people's validation studies use as the reference. That is the strongest recommendation a sensor can have.
Price as of October 22, 2026. Prices move; Amazon's is the one that counts.
#ad · we may earn a commission from this link to Polar H10
The short answer
No Garmin optical wrist sensor has been validated against an ECG reference in any published study we could find. The Garmin measurements that do exist are unflattering: a Garmin wrist watch recorded roughly 33 bpm of bias during burpees in a 2025 study, the largest error in it, and a Garmin came fourth of five on overnight HRV in a 536-night ECG comparison.
Ranked
Quick picks
| # | Device | Best for | Evidence | Score | Price |
|---|---|---|---|---|---|
| 01 | ![]() Polar H10 The device other people's validation studies use as the reference. That is the strongest recommendation a sensor can have. | Anyone who trains by heart rate | Peer-reviewed validation | 8.9/10 | $104.45Amazon |
| 02 | ![]() Polar Verity Sense The optical armband that measured a bias under 0.1 bpm against a chest strap on a graded treadmill test. The comfortable answer. | Strap-quality data without the strap | Peer-reviewed validation | 8.4/10 | $104.95Amazon |
| 03 | ![]() Garmin HRM 600 The strap to buy if you are already inside Garmin's ecosystem and want running dynamics with it. | Garmin owners wanting running dynamics | Manufacturer specification | 7.4/10 | $157.70Amazon |
#ad· Live prices from the Amazon Product API, as of October 22, 2026. Where we have no verified live price we show none. Scores come from the published rubric at How we rank — the Evidence column shows what each ranking actually rests on, including where the answer is nothing.
The short version, and why the question is harder than it looks
"Is Garmin heart rate accurate" sounds like a question with a percentage for an answer. It does not have one, and the reason is not that Garmin is secretive. It is that the published validation literature for consumer wearables is far thinner than the product marketing implies. The 2024 umbrella review — 24 systematic reviews, 249 primary validation studies, 430,465 participants — found that roughly 34 of the 310 consumer wearables it identified had ever been validated at all.
That same review gives the category-level figure most often quoted for heart rate: approximately ±3% error, with a mean bias of −3.39 bpm, across every device and protocol it covered. That is the honest ceiling on what anyone can tell you about a device nobody has measured — it is a statement about wrist optical sensing in general, not about any Garmin watch in particular, and the authors declined to pool a meta-analysis precisely because the protocols, devices and reference instruments varied so much.
Every Garmin figure in the published record
Below is the complete set of published measurements we have been able to find that involve a Garmin device and heart rate, or a metric derived from it. The column that matters is the last one: what the study actually measured.
| Garmin device | What was measured | Finding |
|---|---|---|
| Forerunner 55 (wrist) | Heart rate during burpees, against a Polar H10 chest strap | Bias of approximately 33 bpm — the largest error recorded in the study |
| fēnix 6 | Nocturnal HRV across 536 nights, against single-lead ECG at 1000 Hz | 0.87 concordance, 10.52% error — fourth of five devices, described by the authors as poor agreement |
| fēnix 6 | Nocturnal resting heart rate, same study | Excluded from the comparison: the 30-minute window Garmin uses is not timestamped, so it could not be aligned with the reference |
| Forerunner 265 / 265s | Lactate threshold heart rate and pace, against a graded exercise test (n = 23) | Threshold pace overestimated by 25.78%; a usable estimate returned in 65.2% of attempts |
| Forerunner 230 and 245, fēnix 3, 6 and 7 | VO2 max and lactate threshold, in a 13-study systematic review | Reviewed rather than ranked; the authors state that undisclosed algorithms prevent cross-device comparison and that none of the studies tested current models |
| Forerunner 970, 570, 165, fēnix 8, Venu 3, Venu 4, Instinct 3 and every other current model | Wrist heart rate | No validation study of any kind exists that we could find |
Read the table as a whole and the shape of the answer appears. Garmin's wrist sensor has never been measured against ECG in a published study we could find. What has been measured is a cheap Forerunner at high intensity, an old fēnix overnight, and two heart-rate-derived model outputs — and all four results were poor. Every watch Garmin currently sells is in the bottom row.
The one direct measurement, in context
The 2025 anatomical-placement study is the only published work we found that put a Garmin wrist sensor against a reference instrument during exercise. Twenty-eight participants wore a Polar H10 as the criterion, plus a Polar Verity Sense on the forearm, a Garmin Forerunner 55 on the wrist and three Whoop 4.0 units at wrist, forearm and upper arm, across rest, a cycling warm-up, burpees and a modified Bruce treadmill protocol.
The Garmin recorded roughly 33 bpm of bias during the burpee block — the worst number in the study. Two caveats belong with that, and we would rather state them than let the headline do more work than it should. The Forerunner 55 is an entry-level watch from an older sensor generation, so it is the weakest Garmin rather than a representative one. And burpees are close to the hardest condition you can give an optical sensor: rapid wrist flexion, grip tension and intensity changing every few seconds.
The study's own conclusion was not about brands at all. It was that position dominated: the forearm and upper-arm devices held agreement where wrist devices lost it. That matters here because every Garmin watch is, by definition, a wrist device. The mechanism, and what it means for your own data, is in wrist versus chest-strap accuracy.
What Garmin itself does when the number has to be right
The most useful evidence about Garmin's wrist sensor is not a study result. It is what Garmin and the researchers who test Garmin watches do when accuracy is actually load bearing.
- In the 100-runner lactate threshold study, the authors note that the Garmin protocol required an ECG chest strapwhile the other two devices used wrist optical sensing. Garmin's own guided threshold test will not run on the wrist sensor alone.
- Garmin sells three current chest and clip straps and publishes a buying guide for choosing between them, attributing step speed loss, stride length, vertical oscillation and ground contact time balance to the HRM 600. Those metrics are strap-only by design.
- Garmin's own manual states that the watch sets your default heart rate zones from your user profile, that "for the most accurate calorie data during your activity, set your maximum heart rate", and that while lactate threshold heart rate can be auto-detected, maximum heart rate cannot.
None of that is an admission of anything. Every brand sells straps. But it is a consistent signal: the manufacturer builds its most measurement-sensitive features around an external electrical sensor, and asks you to supply the one number the watch cannot work out for itself.
The error that is probably bigger than your sensor
Before buying anything, check the setting, because the zone arithmetic can swamp the sensor error. Garmin's default zones come from your profile, and the convention most profiles inherit is 220 minus your age — Polar's own training guide calls that "the most simple way" to estimate maximum heart rate, which is a fair description and not a validation.
Work it through. At 40 years old the convention gives a maximum of 180, so a zone 2 ceiling at 70% lands on 126 bpm. If your true maximum is 190, the ceiling is 133. That is a seven-beat shift in a ten-beat window, caused by a rule of thumb rather than by any sensor — and it is free to fix by setting a measured maximum. The full version of this argument, with the device field it changes, is in heart rate monitors for zone 2 training and heart rate zones explained.
So when is a Garmin's wrist heart rate good enough?
A defensible reading of the record, stated as a judgment rather than a measurement:
- Steady efforts, probably fine. The category-level ±3% from the umbrella review describes mostly steady-state protocols, and the one optical device measured on a graded treadmill in the placement study did very well — bias under 0.1 bpm, concordance 0.997. That device was worn on the forearm, not the wrist, which is the caveat.
- Intervals, lifting and anything with grip, not reliably.This is where the burpee result lives, and where the one independent test of a rival brand's watch also found divergence during rapid intensity change.
- Overnight HRV and recovery scores, treat as trend data. The only Garmin overnight measurement on record was fourth of five and the authors called it poor. Every Garmin score built on that signal — HRV status, Body Battery, training readiness — inherits it. We work through one of those in is Body Battery accurate.
The fix, ranked — and what it costs
If you want your Garmin's heart rate to be right rather than roughly right, the answer is not a different watch: it is an external sensor, and every current Garmin pairs one over ANT+ or Bluetooth. The three below are ranked on our published rubric, which weights the strength of the validation record most heavily. One of them is the instrument researchers measure other devices against; one of them has the best optical result we have found; one of them is Garmin's own, and has never been independently measured at all.
A note on ordering, because it matters more than the ranking: if the strap you buy is one you will not wear, you have downgraded your data rather than upgraded it. An unworn ECG strap measures nothing, and a wrist sensor you actually wear beats it every single time.
In full
Every pick, and why
Polar H10
The device other people's validation studies use as the reference. That is the strongest recommendation a sensor can have.
- Sensor
- Electrical (ECG), chest strap
- Connectivity
- Bluetooth LE + ANT+
- Memory
- One session, up to 30 hours
- Battery (stated)
- Up to 400 h, CR2025 coin cell
- Water rating
- WR30
What's good
- Used as the criterion measure in published research — including the 2025 Sensors placement study on this site
- Simultaneous Bluetooth and ANT+, so it pairs to a watch and a bike computer at once
- 400 stated hours on a coin cell you replace rather than recharge
What isn't
- It is a chest strap, and a chest strap is less comfortable than a watch
- The strap wears out well before the sensor does
Skip this if
Skip this if you know yourself well enough to know you will not wear it. An unworn ECG strap measures nothing, and a wrist sensor you actually wear beats it every time.
What the evidence says
Peer-reviewed validationUsed as the reference standard in Sensors (2025), the anatomical-placement study of 28 participants. Being chosen as the criterion is an implicit validation by the researchers, though it means the study cannot measure the H10's own error.
Show how this 8.9 was calculated
| Factor | Weight | Score |
|---|---|---|
| EvidenceResearchers use it as the criterion measure. Nothing else in this category has a stronger evidentiary position. | 30% | 10.0 |
| HardwareElectrical ECG measurement rather than optical — a different and better physical principle for this job. | 20% | 9.5 |
| Metric coverageHeart rate and R-R intervals only; it does not pretend to do anything else. | 20% | 6.5 |
| Endurance400 stated hours on a replaceable coin cell. | 15% | 9.5 |
| Cost per capabilityInexpensive next to any watch, and it outlasts several of them. | 15% | 8.5 |

Price as of October 22, 2026. Prices move; Amazon's is the one that counts.
#ad · we may earn a commission from this link to Polar H10
Polar Verity Sense
The optical armband that measured a bias under 0.1 bpm against a chest strap on a graded treadmill test. The comfortable answer.
- Sensor
- Optical, forearm or upper-arm band
- Connectivity
- Bluetooth (dual) + ANT+
- Modes
- Live streaming, on-board recording, swim mode
What's good
- Sensors (2025) recorded the smallest bias of any device tested on the graded treadmill protocol — under 0.1 bpm, CCC = 0.997
- Lowest resting error in the same study, at roughly 1.6% MAPE
- Far more comfortable than a chest strap, and it works under a wetsuit
What isn't
- Still an extra device to charge and remember
- Like every optical sensor, it struggled in the same study's burpee protocol — nothing optical handles that well
Skip this if
Skip this if your training is mostly explosive, stop-start work. In the burpee protocol every optical device tested fell below 0.50 concordance, this one included. Buy the H10 for that.
What the evidence says
Peer-reviewed validationDirectly measured in Sensors (2025), n = 28, against a Polar H10 reference: lowest resting MAPE at ~1.6 ± 0.8%, and the smallest bias on the modified Bruce treadmill protocol at under 0.1 bpm (CCC = 0.997).
Show how this 8.4 was calculated
| Factor | Weight | Score |
|---|---|---|
| EvidenceDirectly measured in a peer-reviewed study, with the best result of any optical device tested. | 30% | 9.5 |
| HardwareOptical, but worn on the forearm — the placement the same study found outperforms the wrist. | 20% | 8.5 |
| Metric coverageHeart rate plus on-board recording and a swim mode. | 20% | 7.0 |
| EnduranceRechargeable, with stated endurance comfortably covering long sessions. | 15% | 8.0 |
| Cost per capabilityPriced against a good chest strap, not against a watch. | 15% | 8.5 |

Price as of October 22, 2026. Prices move; Amazon's is the one that counts.
#ad · we may earn a commission from this link to Polar Verity Sense
Garmin HRM 600
The strap to buy if you are already inside Garmin's ecosystem and want running dynamics with it.
- Sensor
- Electrical (ECG), chest strap
- Extras
- Running dynamics, HRV data, on-board storage
What's good
- Adds running dynamics that a watch alone cannot compute
- Stores data when out of watch range and syncs later
What isn't
- Costs meaningfully more than the Polar H10 without a published validation advantage
- Its extra metrics only fully surface inside Garmin's own platform
Skip this if
Skip this if you just want accurate heart rate. You would be paying a premium over the H10 for running-dynamics metrics most runners look at twice and never again.
What the evidence says
Manufacturer specificationGarmin publishes specifications but no validation study we could find. It is an electrical chest strap, which is the right physical principle — but 'right principle' is not the same as 'measured accuracy'.
Show how this 7.4 was calculated
| Factor | Weight | Score |
|---|---|---|
| EvidenceCorrect sensor principle, detailed published specs, no independent validation we could find. | 30% | 6.0 |
| HardwareElectrical ECG measurement with on-board storage. | 20% | 9.0 |
| Metric coverageHeart rate, HRV and the full running-dynamics set. | 20% | 8.5 |
| EnduranceGood stated endurance; rechargeable. | 15% | 8.0 |
| Cost per capabilityA clear premium over the H10 without a matching evidence advantage. | 15% | 6.0 |

$169.997% off
Price as of October 22, 2026. Prices move; Amazon's is the one that counts.
#ad · we may earn a commission from this link to Garmin HRM 600
How to pair one to a Garmin, and what you gain
Every current Garmin watch pairs external heart rate sensors over ANT+ or Bluetooth — the Venu 4 manual is explicit about it, naming the HRM 200, HRM 600, HRM-Fit and HRM-Pro series, and the running watches have supported external straps for far longer. Pair once in the sensors menu and the watch prefers the strap for activities while continuing to use the wrist sensor for all-day and overnight data.
That last detail is the limit of this upgrade and it is worth being clear about: a strap fixes your activity heart rate. It does not usually fix overnight HRV, resting heart rate or the recovery scores built from them, because you are not going to sleep in a chest strap. If the overnight numbers are what you care about, the HRV monitors page is the right field, and the honest answer there is also a different device.
Two practical points from the manufacturers' own documentation. The Polar H10 stores one session of up to 30 hours on its own and runs up to 400 hours on a replaceable CR2025 cell; the Garmin HRM 600 is rechargeable, rated up to two months at an hour per day, and 5 ATM. Strap failures are far more common than sensor failures, and they look exactly like a dying battery — the diagnostic order is in the H10 battery and strap guide.
What this page is not saying
It is not saying Garmin is worse than its competitors. Almost nothing in this category has been validated: Polar's current watches, COROS's, Suunto's and Apple's wrist sensors are all in the same empty row of the heart rate accuracy table. Garmin appears in more studies than any other brand partly because researchers reach for Garmin watches, and a brand that shows up in the literature at all is being held to a standard its rivals have simply avoided.
It is also not saying your Garmin is lying to you. Absence of evidence is not evidence of error — it is absence of evidence, which is a different and more frustrating thing. What we can say is that nobody has published a measurement that would let anyone, including Garmin, put a number on the wrist sensor's accuracy; that the few Garmin-adjacent results that exist are unflattering; and that the one upgrade with peer-reviewed evidence behind it costs about a tenth of a flagship watch.
Questions
Frequently asked
Is Garmin's wrist heart rate monitor accurate?
No published study we could find has validated a Garmin wrist optical sensor against an ECG reference, so there is no accuracy figure for it. The closest measurement — a Forerunner 55 during burpees in a 2025 study — recorded roughly 33 bpm of bias, the largest error in that study. For steady efforts the category-level estimate of about ±3% is the best available guide, and it is not Garmin-specific.
Is a chest strap more accurate than a Garmin watch?
On the published record, yes, and by a wide margin of evidence rather than a measured percentage: researchers use the Polar H10 as the criterion instrument they measure other devices against, and no Garmin wrist sensor has ever been validated at all. The physical principle differs too — a strap measures the heart's electrical signal, a watch infers rate from light reflected through skin.
Is Garmin HRV accurate?
In the only study we found that measured it, a Garmin fēnix 6 came fourth of five devices across 536 nights against single-lead ECG, at 0.87 concordance and 10.52% error — the authors called that poor agreement. It was also dropped from the resting-heart-rate comparison because its 30-minute measurement window is not timestamped. See HRV accuracy by device.
Will a chest strap make Garmin's Body Battery or sleep data better?
Mostly no, and this is the most common misunderstanding about the upgrade. A strap improves heart rate during recorded activities. Body Battery, HRV status and sleep staging are built largely from overnight data captured by the wrist sensor, and you are unlikely to sleep in a chest strap. Those scores stay exactly as unvalidated as they were.
Which Garmin watch has the most accurate heart rate?
Nobody can answer that from evidence, because no current Garmin has been independently measured — so any site ranking Garmin models by heart-rate accuracy is ranking spec sheets and calling it measurement. If accuracy is your deciding factor, the choice that changes your data is the sensor you add, not the model you pick. Our Garmin-specific strap field is the best heart rate monitors for Garmin watches.
Show your working
Sources
Every one of these was read in full before it was cited. Where we could not access a paper, we do not quote its numbers.
- [1]Peer-reviewed validation2025“Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities”, Sensors (Basel)
n = 28 (14 male, 14 female). Polar H10 chest strap as the reference. Compared Polar Verity Sense (forearm), Garmin Forerunner 55 (wrist) and three simultaneous Whoop 4.0 units at wrist, forearm and upper arm, across rest, cycling warm-up, burpees and a modified Bruce treadmill protocol.
- [2]Peer-reviewed validation2025Dial, Hollander, Vatne, Emerson, Edwards & Hagen, “Validation of nocturnal resting heart rate and heart rate variability in consumer wearables”, Physiological Reports 13(16):e70527
DOI 10.14814/phy2.70527. n = 13 healthy adults (7 male, 6 female, 33.2 ± 8.6 years) across 536 nights, each wearing an Oura Gen 3, Oura Gen 4, Polar Grit X Pro, Garmin fēnix 6 and Whoop 4.0 simultaneously against a Polar H10 single-lead ECG reference sampled at 1000 Hz. Authors’ stated limits: healthy adults only, no atrial-fibrillation population, proprietary and periodically-updated algorithms, and unequal night counts per device. The Garmin was dropped from the resting-heart-rate comparison because the 30-minute window it uses is not timestamped.
- [3]Peer-reviewed validation2024Doherty, Baldwin, Keogh, Caulfield & Argent, “Keeping Pace with Wearables: A Living Umbrella Review of Systematic Reviews Evaluating the Accuracy of Consumer Wearable Technologies in Health Measurement”, Sports Medicine
DOI 10.1007/s40279-024-02077-2. An umbrella review: 24 systematic reviews covering 249 unique primary validation studies and 430,465 participants (43% female), across 11 biometric outcomes, with roughly 34 of 310 identified consumer wearables ever validated. Reported accuracy by metric: heart rate approximately ±3% (mean bias −3.39 bpm); step count mean absolute percentage error from −9% to 12%; energy expenditure mean bias −3 kcal per minute with error ranging from −21.27% to 14.76%. Authors’ stated limits: a temporal lag between device release and published research, the intrinsic bias of a tertiary synthesis, and heterogeneity of protocols, devices, criterion measures and statistics severe enough that the authors did not pool a meta-analysis.
- [4]Peer-reviewed validation2025Lu, Cui, Zhu, Wu, Xing, Pan & Shen, “Validity of smartwatch-derived estimates of lactate threshold heart rate and pace compared to graded exercise testing”, Frontiers in Physiology 16:1621996
DOI 10.3389/fphys.2025.1621996. 100 healthy recreational runners (61 male, 39 female, 28.0 ± 9.6 years) against a treadmill graded exercise test with fingertip blood lactate (Biosen C-line), threshold determined by the modified Dmax method. Device counts were unequal: Huawei GT Runner n = 100, Garmin Forerunner 265/265s n = 23, COROS PACE 3 n = 17. Authors’ stated limits: unbalanced samples, indoor reference against outdoor watch tests, day-to-day threshold variability, and different heart-rate acquisition between devices — the Garmin protocol required an ECG chest strap while the other two used wrist PPG — plus undisclosed manufacturer algorithms.
- [5]Peer-reviewed validation2025Železnik Mežan, “Accuracy of wearables for determining the maximal oxygen uptake and lactate threshold: a qualitative systematic review”, Frontiers in Sports and Active Living 7:1707991
DOI 10.3389/fspor.2025.1707991. 13 studies, 273 participants (181 men, 92 women), covering Garmin Forerunner 230 and 245, fēnix 3, 6 and 7, Polar V800, Apple Watch Series 7, foot-worn IMUs including Stryd, and chest-worn GNSS. Authors’ stated limits: screened and extracted by a single reviewer, small per-study samples, none of the studies tested the latest smartwatch models, undisclosed algorithms prevent cross-device comparison, and the pooled population skewed to 18-30 year olds.
- [6]Manufacturer specification2026Garmin — Forerunner 265 Series owner's manual, “Setting Your Heart Rate Zones”
Manufacturer-stated, read 2026-09-18. Garmin states that “the watch uses your user profile information from the initial setup to determine your default heart rate zones”, that “for the most accurate calorie data during your activity, set your maximum heart rate”, and that zones can be based on BPM, “%Max. HR” or “%HRR” (heart rate reserve, defined in the manual as maximum heart rate minus resting heart rate). Lactate threshold heart rate is entered separately and can be auto-detected; maximum heart rate is not.
- [7]Manufacturer claim only2025Garmin — “Which Garmin heart rate monitor is right for you?”
Garmin’s own buying guide, dated 9 September 2025 and read 2026-08-26. It presents three straps — HRM 200, HRM-Fit and HRM 600 — and attributes step speed loss, stride length, vertical oscillation and ground contact time balance to the HRM 600. The HRM-Pro Plus does not appear in it. Tiered as a manufacturer claim rather than a specification: it is marketing copy, and we use it only for what Garmin says its own current line-up is.
- [8]Manufacturer specification2026Garmin — HRM 600 owner’s manual, specifications
Manufacturer-stated, read 2026-08-18: rechargeable lithium-ion battery rated up to 2 months at 1 hour per day, 5 ATM water rating, operating range 0 to 40 °C, charging range 15 to 42 °C, 2.4 GHz radio at 9.9 dBm maximum. Garmin describes the strap as providing real-time heart rate and HRV data, running dynamics and stand-alone activity recording.
- [9]Manufacturer specification2026Garmin — Venu 4 Series owner’s manual, “Wireless Sensors”
Manufacturer-stated, read 2026-10-11. Garmin states that “your watch can be paired and used with wireless sensors using ANT+ or Bluetooth technology”, and lists the supported sensor types: Club Sensors (Approach CT10), eBike, Extended Display, Heart Rate (HRM 200, HRM 600, HRM-Fit and the HRM-Pro series are named), Foot Pod, Headphones, inReach, Lights, Power (Rally or Vector pedals), Radar, RD Pod, Shifting, Shimano Di2, Smart Trainer, Speed/Cadence and tempe. The US edition of this page was not reachable from here, so the Asia-Pacific edition of the same manual is cited.
- [10]Manufacturer specification2026Polar — H10 heart rate sensor published specifications
Manufacturer-stated: electrical (ECG) measurement, Bluetooth LE + ANT+, internal memory for one session up to 30 hours, up to 400 h on a CR2025 coin cell, WR30.
- [11]Manufacturer specification2026Polar — Verity Sense published specifications
Manufacturer-stated: optical heart rate worn on the forearm or upper arm, dual Bluetooth plus ANT+, on-board recording, swim mode, WR50.
- [12]Manufacturer claim only2026Polar — “Heart Rate Zones”, published training guide
Polar's own published guide, read 2026-09-18. States the five-zone model as percentages of maximum heart rate — zone 1 at 50-60%, zone 2 at 60-70%, zone 3 at 70-80%, zone 4 at 80-90%, zone 5 at 90-100% — and that the “most simple way” to establish maximum heart rate is “the rule 220-your age”. Tiered as a manufacturer claim rather than a specification: it is training guidance, and the zone boundaries themselves are a convention, not a measurement.
Read next
Related
- Heart rate accuracy by device
The same question asked across every brand, including the empty rows.
- Wrist vs chest strap accuracy
Why sensor position beats brand, with the study that measured it.
- Best heart rate monitors for Garmin
Which strap to pair, by connection type and metric.
- Upgrade path: better heart rate accuracy
The cheapest route from a watch you own to data you can act on.